Vehicle Control Unit
VCU_v30
Applications
Electric & Hybrid vehicle control unit
- Driving Strategy Control
- Hybrid Engine Speed & Load Control
- Cluster Control
- BCM & CAN gateway Control
- On Board Charge Control
- Quick Charge Control
- Passenger Car & Light-duty Vehicle (12V) to Bus & Heavy-duty Vehicle (24V)
Specifications
Parameter | ||
Operating Voltage | 6V ~ 32V | |
Maximum Supply Voltage | 36V | |
Standby Current | < 1mA | |
Supply Current(without load) | 200mA@12V | |
Total Load Current | 60A | |
Operating Temperature | -40°C ~ +125°C | |
Degree of Protection | IP67 & IP6k9k | |
Weight | 730 g | |
Standards | ||
Electrical | HMC | ES96200-00 ES96202-01 ES95400-10 ES95682-00 |
ECE | ECE R10.3 | |
Vibration & Impact | HMC | ES95400-10 |
Environmental | HMC | ES95400-10 |
Features
Microprocessor
- SAK-XC2299H-200F100L (Infineon)
- 100 MIPS Performance @ 100 MHz Frequency
Memory
- 1.6MB on-chip flash memory
- 138kB on-chip RAM
- 16kB on-chip EEPROM
Inputs
- Digital Inputs (0 ~ 32V)
- 4 x Digital Input for Wake up(3 x DIH(Digital Input High), 1 x DIL(Digital Input Low))
- 8 x DIH (High-side Digital Input)
- 10 x DIX (Configurable Digital Input) Default: 7 x DIH, 3 x DIL
- Analog Input
- 2 x Potentiometer for APS & BPS
- 2 x Pressure Sensor
- 2 x NTC Sensor
- 2 x Common mode A/D (Configurable 0 to 32V input)
- Normal Charge(OBC) Connector Proximity (SAE J1772)
- Frequency Input
- 1 x High speed frequency signal input (Internal pull-up)
- Normal Charge(OBC) Pilot input (SAE J1772)
- Quick Charge Pilot Input
Outputs
- 16 x DOL (Digital Output Low)
- 2 x 1.1A, 12 x 2.2A , 2 x 3.3A Low-side out.
- PWM output (up to 10kHz)
- 4 x DOH (Digital Output High)
- All DOH port up to 5A High-side output with current sensing.
- PWM output (up to 2kHz)
- 6 x High & Low Side Output
- 4 x 10A, 2 x 5A High side & Low side output with high-side current sensing.
- PWM output (up to 20kHz)
- Motor Driver for half bridge & full bridge.
Communications
- 4 x CAN Interface (HS CAN)
- Baud Rate : 50kbps - 1Mbps
- All CAN Termination with internal circuit (default)
- CAN Gateway Function
- LIN Interface
- RS-232 Interface (up to 200kbps)
Sensor Supply
- 6 x Sensor Supply Output (5V 400mA)
Protection
- Load dump protection
- Over voltage protection
- Revers voltage protection
Others
- Monitoring of board temperature, supply voltage and sensor supply.